Fujitsu 12.5Kw Standard Cassette Reverse Cycle Air Conditioner
Fujitsu Indoor AUTA45LCLU Outdoor AOTA45LCTL
Incorporating the latest fan technology, these units fit neatly into the ceiling and distribute conditioned air through 3 or 4 sides of the unit.
12.5Kw Standard Cassette Reverse Cycle Air Conditioner
Up/Down Swing Louvre
The up/down louvre automatically swings up and down.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Washable Panel
Unit has a washable panel
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only
Weekly Timer
Different on-off times can be set for up to 7 days.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.
Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.
Connectable Fresh Air Duct
Allows introduction of fresh air to occupied space.
The up/down louvre automatically swings up and down.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Washable Panel
Unit has a washable panel
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only
Weekly Timer
Different on-off times can be set for up to 7 days.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.
Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.
Connectable Fresh Air Duct
Allows introduction of fresh air to occupied space.
Specification
- Model No. - Indoor
- AUTA45LCLU
- Model No. - Outdoor
- AOTA45LCTL
- Reverse Cycle System
- Yes
- Cooling Capacity (Watts)
- 12,500
- Cooling Capacity (BTU/h)
- 42,700
- Range (Watts)
- 4,000-14,000
- Range (BTU/h)
- 13,700-47,800
- Heating Capacity (Watts)
- 14,000
- Heating Capacity (BTU/h)
- 47,800
- Range (Watts)
- 4,200-16,200
- Range (BTU/h)
- 14,300-55,300
- Power Supply (Volts)
- 240
- Phase-Frequency (Ph - Hz)
- 1-50
- Power Supply Attachment
- Outdoor
- Running Current, Cooling (Amps)
- 16.3
- Running Current, Range (Amps)
- Max 20.0
- Input, Cooling (Watts)
- 3,890
- Input, Range (Watts)
- Max 4,900
- Running Current, Heating (Amps)
- 16.1
- Running Current, Range (Amps)
- Max 20.0
- Input, Heating (Watts)
- 3,830
- Input, Range (Watts)
- Max 4,900
- Moisture Removal (l/hr)
- 4.5
- E.E.R. - Cooling
- 3.21
- C.O.P. - Heating
- 3.66
- Star Rating - Cooling
- 1.5
- Star Rating - Heating
- 2.5
- Fan Speed
- 4
- Air Circulation, High (l/s)
- 528
- Compressor Type
- Twin Rotary
- Dimensions - Inside Unit (HxWxD Mm)
- 288(50)x840(950)x840(950) (Grill)
- Weight - Inside Unit (kg)
- 27 (5.5) (Grill)
- Dimensions - Outside Unit (HxWxD Mm)
- 1290x900x330
- Weight - Outside Unit (kg)
- 86
- I.U. Sound Pressure Level (dBA@1mtr)
- 46
- O.U. Sound Pressure Level (dBA@1mtr)
- 55
- O.U. Sound Power Level (dBA)
- 69
- Refrigerant Type
- R410A
- Connection Pipe Sizes, Gas (mm)
- 15.88
- Connection Pipe Sizes, Liquid (mm)
- 9.52
- Pre Charged Length (Metre)
- 20
- Minimum Pipe Length (Metre)
- 5
- Maximum Pipe Length (Metre)
- 50
- Maximum Pipe Height (Metre)
- 30
- Pipe Connection Methods
- Flare
- Outdoor Operating Temp, Cooling Degrees C
- -15 to 46
- Outdoor Operating Temp, Heating Degrees C
- -15 to 24