Fujitsu 5.2Kw Compact Cassette Reverse Cycle Air Conditioner
Fujitsu Indoor AUTG18LVLA Outdoor AOTG18LACC
Incorporating the latest fan technology, these units fit neatly into the ceiling and distribute conditioned air through 3 or 4 sides of the unit.
5.2Kw Compact Cassette Reverse Cycle Air Conditioner
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Filter sign
Indicates the filter cleaning period by lamp.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.
Weekly Timer
Different on-off times can be set for up to 7 days.
The auto shut louvres close or open automatically when the unit stops or starts.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Filter sign
Indicates the filter cleaning period by lamp.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.
Weekly Timer
Different on-off times can be set for up to 7 days.
Specification
- Model No. - Indoor
- AUTG18LVLA
- Model No. - Outdoor
- AOTG18LACC
- Reverse Cycle System
- Yes
- Cooling Capacity (Watts)
- 5,200
- Cooling Capacity (BTU/h)
- 17,700
- Range (Watts)
- 900-5,900
- Range (BTU/h)
- 3,100-20,100
- Heating Capacity (Watts)
- 6,000
- Heating Capacity (BTU/h)
- 20,500
- Range (Watts)
- 900-7,500
- Range (BTU/h)
- 3,100-25,600
- Power Supply (Volts)
- 240
- Phase-Frequency (Ph - Hz)
- 1-50
- Power Supply Attachment
- Outdoor
- Running Current, Cooling (Amps)
- 6.6
- Running Current, Range (Amps)
- Max 9.6
- Input, Cooling (Watts)
- 1,560
- Input, Range (Watts)
- Max 1,990
- Running Current, Heating (Amps)
- 7.0
- Running Current, Range (Amps)
- Max 13.1
- Input, Heating (Watts)
- 1,660
- Input, Range (Watts)
- Max 2,500
- Moisture Removal (l/hr)
- 2.2
- E.E.R. - Cooling
- 3.33
- C.O.P. - Heating
- 3.61
- Star Rating - Cooling
- 2
- Star Rating - Heating
- 2.5
- Fan Speed
- 4
- Air Circulation, High (l/s)
- 189
- Compressor Type
- DC Rotary
- Dimensions - Inside Unit (HxWxD Mm)
- 245(49)×570(700)×570(700) (Grille)
- Weight - Inside Unit (kg)
- 15 (2.6) (Grille)
- Dimensions - Outside Unit (HxWxD Mm)
- 620×790×290
- Weight - Outside Unit (kg)
- 41
- I.U. Sound Pressure Level (dBA@1mtr)
- 43
- O.U. Sound Pressure Level (dBA@1mtr)
- 55
- O.U. Sound Power Level (dBA)
- 71
- Refrigerant Type
- R410A
- Connection Pipe Sizes, Gas (mm)
- 12.70
- Connection Pipe Sizes, Liquid (mm)
- 6.35
- Pre Charged Length (Metre)
- 15
- Minimum Pipe Length (Metre)
- 3
- Maximum Pipe Length (Metre)
- 30
- Maximum Pipe Height (Metre)
- 20
- Pipe Connection Methods
- Flare
- Outdoor Operating Temp, Cooling Degrees C
- -10 to 46
- Outdoor Operating Temp, Heating Degrees C
- -15 to 24